Piping Insulation: Types of Pipe Insulation

Pipe Insulations are materials or combinations of materials wrapped around the pipe which retard the flow of heat energy. Pipe insulation reduces energy losses to a great extent and thereby reduce energy cost. Piping shall be insulated as per the insulation class, operating temperature, and insulation thickness stated in the P&ID.

Functions of Pipe Insulation

A piping insulation system serves three principal purposes:  

  1. The significant reduction in heat transfer of thermal energy to and from the surface of the piping system (Heat Conservation). So, piping insulation conserves energy.
  2. The prevention of moisture formation and collection on the surface of the piping system due to condensation on cold surfaces (Cold Insulation).
  3. The prevention of potentially injurious personnel contact with the surface of the exposed piping system (Personal Protection).

However, there are various other benefits of piping insulation as listed below

  • Piping insulation facilitates temperature control of the process.
  • Prevent vapor flow and water condensation on cold surfaces.
  • Increase the operating efficiency of heating/cooling, power, and process systems.
  • Reduce major damages in the piping during fire or accidents.
  • Prevent pollutant emissions to the atmosphere to a great extent.
  • Sometimes Steam traced/Electric traced insulation, Regeneration insulation, jacketing, etc. are used as per process/licensor requirements.
  • Fireproofing, fire protection, and acoustic insulation (to control noise and absorb vibration) are provided based on project specifications/ ITB requirements.
Hot and Cold Pipe Insulation
Fig. 1: Hot and Cold Pipe Insulation

Pipe Insulation Types

Piping insulation can be classified based on various parameters like

  • Based on the Pipe Insulation Function
    • Hot Insulation
    • Cold Insulation
    • Personal Protection Insulation
    • Acoustic Insulation
  • Based on Insulation Material Types
    • Fibrous Insulation
    • Cellular Insulation
    • Granular Insulation

Piping Insulation Types Based on the Function of Pipe Insulation

Hot Insulation

Hot insulation is applied on the hot surfaces of the piping system to prevent the energy flow from flowing fluid. So, the main aim of hot piping insulation is heat conservation. Mineral Wool, Glass Wool, Calcium Silicate, etc. are normally used as Hot insulating material. Hot Piping Insulation is typically applied for process temperatures above 60°C.

Cold Insulation

Cold Insulation is the insulation used on cold surfaces of the piping system to avoid heat gain from outside (Cold Conservation) or to avoid Condensation. Polyurethane Foam, Expanded Perlite Foam, Expanded Polystyrene Foam, etc. are the widely used cold insulating materials.

Personal Protection Insulation

Personal Protection insulation is provided to avoid personal heat injury. All exposed piping surfaces that exceed 60 degrees C are provided with personal protection insulation. The areas that are not accessible by construction or operating personnel can be left exposed. An open mesh metal guard (Fig. 2), mineral wool, etc. are used as personal protection insulation material.

READ  Process Engineering Deliverables for EPC of Oil and Gas Industries

The criteria for personal protection is that the exposed surfaces located within 600 mm horizontally or 2100 mm vertically of a normal access, walkway, or work area are to be insulated.

Acoustic insulation

Acoustic Insulation is provided for all piping that is considered a potential sound source. The main purpose is to reduce the noise (vibration) to an acceptable limit. The minimum thickness for acoustic insulation is normally 75 mm. Acoustic Foam, fiberglass, polyester/polyurethane foams, rock wool, Mass Loaded Vinyl, etc. are used as Acoustic Insulating material.

Personal Protection Insulation in Operating Plant
Fig. 2: Personal Protection Insulation in Operating Plant

Piping Insulation Types based on insulation material types

Fibrous Insulation

Fibrous insulation consists of small diameter fibers which finely divide the air space. The fibers may be perpendicular or parallel to the surface being insulated, and they may or may not be bonded together.

Common fibers used in piping insulation are Silica, slag wool, rock wool, and alumina-silica. Among these, Glass fiber and Mineral Wool are the two most widely used piping insulations of this type. Their fibers are normally bonded with organic binders for structural integrity.

Cellular Insulation

Cellular pipe insulation material comprises small individual cells separated from each other. Common cellular material used as pipe insulation is glass or foamed plastics such as cellular glass, phenolic foam, or nitrile rubber.

Typical Piping Insulation for Bends
Fig. 3: Typical Piping Insulation for Bends

Granular Insulation

Small nodules containing voids or hollow spaces constitute granular insulation. As gas can be transferred between the individual spaces, It is not considered a true cellular material. This type is manufactured as loose or pourable material or combined with a binder and fibers. Sometimes they undergo a chemical reaction to form rigid insulation. Calcium silicate and vermiculite are examples of these types of insulations.

Pipe Insulation Material

  • Low-temperature insulation is frequently made of expanded cellular plastic or foam rubber material.
  • Moderate temperature insulations are made from grass fiber products.
  • High-temperature insulation is made of preformed cementations or refractory materials or blankets made from ceramic fibers.
  • Insulation and accessory materials have to be 100% asbestos-free.
  • Normally mineral fiber, cellular glass, ceramic fiber, glass fiber, polyisocyanurate, polyurethane foam, Rockwool, Glass Wool, Expanded Perlite, Flexible Elastomeric Foam (FEF), Flexible aerogel blanket, Calcium magnesium silicate wool (CMS), Alkaline earth silicate wool (AES), Calcium Silicate, etc. are used as pipe insulation material.
READ  Dynamic Analysis of Piping System

The following table provides details of some commonly used insulation materials:

Pipe Insulation MaterialDensity (kg/m3)Temperature Limitation
Mineral Glass Fibre up to 535°C
Mineral Wool140up to 700°C
Rock Wool140up to 550°C
Glass Wool80up to 450°C
Calcium Silicate200-280up to 815°C
Expanded Perlite192up to 550°C
Expanded Silica up to 535°C
Refractory Fiber150up to 1750°C
Polyurethane Foam40from -150°C to 110°C
Polyisocyanurate40-64from -150°C to 125°C
Cellular Glass147up to 350°C
Ceramic Fibre250up to 760°C
Pipe Insulation Material Table

Piping Insulation System

The main part of the Piping insulation system is the insulating material. Other elements that constitute the pipe insulation system are

  • Protective Coating
  • Vapor Barrier
  • The cladding of the metallic sheet.
  • Spacers to enable cladding to retain its shape.
  • Packing to fill the cavities or voids, if any.

Pipe Insulation Forms

Insulations are manufactured in a variety of forms to suit specific applications and functions. The installation method is decided by the combined insulation form and type of insulation. The most widely used insulation forms are:

  • Rigid boards, sheets, blocks, and pre-formed shapes: Cellular, granular, and fibrous insulations are produced in these forms.
  • Flexible sheets and pre-formed shapes: Cellular and fibrous insulations are produced in these forms.
  • Flexible blankets: Fibrous insulations are produced in flexible blankets.
  • Cement (insulating and finishing): Produced from fibrous and granular insulations and cement, they may be of the hydraulic setting or airdrying type.
  • Foams: Poured or froth foam used to fill irregular areas and voids. The spray is used for flat surfaces.
Mineral Wool Piping Insulation
Fig. 4: Mineral Wool Piping Insulation

Normally, Rock and Glasswool are pre-formed in two halves; Polyisocyanurate, Polyurethane, and Cellular Glass are supplied in preformed cylindrical shapes to slit in half lengthwise, and ceramic fiber is supplied in blanket strips.

Piping Insulation Standards

The following codes and standards provide guidelines for industrial piping insulation:

  • ASTM C533, ASTM C547, ASTM C552, ASTM C591, ASTM C592, ASTM C610, ASTM C612, ASTM C795, ASTM C892, ASTM C165, ASTM C240, ASTM C302, ASTM C303, ASTM C335, ASTM C356, ASTM C390, ASTM C446, ASTM C680.
  • BS 1902 Part 6, BS 4370 Part 2, BS 5608
  • IS 11239, IS 12436, IS 9428, IS 8183, IS 4671, IS 3690
  • ISO 15665- Acoustic Piping Insulation
  • EN ISO 23993

Factors Affecting Piping Insulation Performance

For any specific application, the main factors that impact the relative performance of various pipe insulation are:

  • Pipe Insulation thickness
  • Thermal conductivity (“k” or “λ” value) of Insulation Material
  • Surface emissivity value or “ε” value
  • Water-vapor resistance (“μ” value)
  • Density of the insulating material
  • Level of moisture content
  • Opening of Joints
READ  What is Pipe Flushing | Criteria for Pipe Flushing

Piping Insulation Thickness Calculation

Click here for details regarding pipe insulation thickness calculation and more details about hot and cold thermal insulation.

Insulated and Non-insulated piping in Operating plant
Fig. 5: Insulated and Non-insulated piping in the Operating plant

Piping Insulation System Design Considerations

Some important design considerations related to piping insulation (May vary from project to project):

  • All insulating materials need to be free from harmful products affecting human health and the environment. To be more specific, the piping insulation material needs to be free from known carcinogens, asbestos, Chlorofluorocarbon (CFCs), Hydrochlorofluorocarbon (HCFCs), heavy metals such as lead or cadmium, and PCBs.
  • Insulation thickness is determined based on pipe size, normal operating temperature,  temperature controlling requirement (extent of heat loss/gain), etc. At a minimum 25 mm pipe insulation thickness is to be used.
  • If the insulation thickness is more than 75 mm then insulation is provided in two or more layers (multi-layer).
  • Insulation shall not be applied until hydrostatic/ pneumatic testing is performed.
  • Insulation up to 12-inch NPS pipe shall be held with SS-304 tie wire and for > 12-inch NPS SS-304 bands are used.
  • All flanges will be insulated other than hydrogen service or high health hazard material services.
  • All valves other than control valves and relief valves shall be insulated.
  • Certain piping items like vents, steam-out and snuffing steam systems, flare and blow-down systems; Piping supports; Steam Traps; Expansion joints, hinged joints and hose assemblies; Instrument connections; Sight flow indicators, etc. are usually not insulated.
  • Each pipe must be insulated separately except where the second pipe is for heat tracing.

Piping Insulation Thickness Chart

A piping insulation thickness chart is a reference chart for piping engineers, designers, and insulation installers when determining the appropriate insulation thickness for various piping systems. The insulation charts are made by economic pipe insulation thickness calculation and presented in a tabular format for easy reference. The piping insulation thickness chart typically includes information on pipe insulation thickness corresponding to the operating temperature range and pipe sizes. A separate table for each type of piping insulation (Hot, cold, or personal protection) is prepared.

The following Image (Fig. 6) shows a typical pipe insulation thickness chart for Heat Conservation Insulation. Note that the image only provides a sample reference for the piping insulation thickness chart, for actual values you must refer to your project-specific data.

Typical Pipe Thickness Insulation Chart for Hot Insulation
Fig. 6: Typical Pipe Thickness Insulation Chart for Hot Insulation

Anup Kumar Dey

I am a Mechanical Engineer turned into a Piping Engineer. Currently, I work in a reputed MNC as a Senior Piping Stress Engineer. I am very much passionate about blogging and always tried to do unique things. This website is my first venture into the world of blogging with the aim of connecting with other piping engineers around the world.

16 thoughts on “Piping Insulation: Types of Pipe Insulation

  1. Nice post! Thanks for the post, I will look forward to see more posts from your blog.

  2. This is on one of the points, “All valves other than control valves and relief valves shall be insulated”. Is this note applicable for manual isolation valves? Is the valves are also insulated and if it is required to operate, how is it done? Please clarify.

  3. Thank-you for this very informed post! I have one question for you – what is the typical cost ($/dia in – foot) for typical insulation with cladding – materials and labour? Thank-you

  4. Excellent write up very informative.

    Can you include how to identify asbestos based installed pipe insulations especially when working with old plants?

  5. Dear Mr. Anoop

    I was impressed on your insulation acumen and I would like to discuss with you for other insulated related business. If you are interested please contact me +91-9176618930

Leave a Reply to Engineers Chaupal Cancel reply

Your email address will not be published. Required fields are marked *